Tapered Roof Board TR/BGM

partially Bonded Torched-on Built-up Bituminous Felt Systems

Tapered Roof BGM is a high performance Polyisocyanurate tapered roof insulation with a polypropylene fleece finished bitumen/glass fibre working surface and a mineral glass facing to the under side. (These boards are not reversible) They are suitable for use below most bitumen based partially bonded built up roofing systems. This product is part of Unilin’s comprehensive range of high performance tapered roof boards providing total solutions for tapered roof projects. An Environmental Product Declaration (EPD), certified by IGBC is available for this product. Please contact technical support for further details.

Additional Infomation

Decks should be primed before the application of the hot bitumen used to bond the vapour control layer. Reference should be made to BS8217 when applying the vapour control layer. Carry the VCL past the insulation and seal with the parapet wall. Torch on VCLs are also available.

the fire rating, when tested to EN 13501-5 and BS 476 Part 3 ‘External Fire Exposure Roof Test’, will be dependent upon waterproofing system specified. external fire exposure roof test

On metal decks, Unilin TR/BGM should be laid break bonded into hot bitumen (max temperature 240°C) mopped or poured over the vapour control layer. The boards can also be mechanically fixed or the mineral coated glassfibre facer (MG) can be adhered with other suitable adhesive. Fixing heads should be sealed with bitumen.

Ensure concrete decks are clean, dry, without projections. Primer should be laid in accordance with the manufacturer’s instructions. The vapour control layer should be fully bonded to the deck and the Unilin TR/BGM should be laid into hot bitumen on the vapour control layer in a break bonded pattern. The boards can also be mechanically fixed or the mineral coated glassfibre facer (MG) can be adhered with other suitable adhesive. Fixing heads should be sealed with bitumen

Partially bonded built–up felt waterproofing should be laid, where in accordance with BS 8217 (Reinforced bitumen membranes for roofing. Code of practice).

The specification for fixing of Unilin roof boards will vary with the location, roof height/width and topographical data, architectural specification should be consulted. Generally with 1200mm x 1200mm boards, a minimum of 4 fixings per board, located between 50mm and 150mm from all edges, additional fixings may be placed along the centre line. Counter sunk washers, 5mm in diameter should be used with each fixing. However, BS 6399 Part 2 or BS EN 1991-1.4: 2005 + A1: 2010 (National Annex to Eurocode 1.Actions on structures. General Actions. Wind Actions) should always be consulted. In two layer systems, all layers should be fixed in accordance with the contained instructions. It is recommended to seek advice from the fixing manufacturer for specific guidance

Related case studies

View Case Studies

274 Bradford Street

The first ever residential square in Birmingham’s creative quarter. The historic Harrison Drape building has been renovated and renamed Fabrick Square. It contains apartments and retail units

View case study

Bristol Airport

We were delighted to work alongside single ply services and assist with the design and supply of 1289m2 of Tapered PIR scheme to Bristol Airport

View case study

Interesed in this product? Contact us today

Consent*

Our related products

View Products

VIP+ Datasheet

VIP+ consists of micro-pourous fumed silica material (silicon carbide, hydrophilic silica, and polyester fibres), contained within a vacuum sealed envelope (multi-layer aluminium foil wrapper), manufactured in accordance with prEN 17140.

View product